" Plates under 12^ pounds per square foot, when ordered to weight, shall not average a greater variation than the following: Up to 75 inches wide, 2^ per cent, above or 2^ per cent, below the theoretical weight. 75 inches wide up to 100 inches wide, 5 per... "
A Treatise on Non-metallic Materials of Engineering: Stone, Timber, Fuel ... - Página 701
de Robert H. Thurston - 1906 - 383 páginas
Vista completa - Acerca de este libro

Public Documents of Massachusetts, Volumen 10

Massachusetts - 1909 - 1182 páginas
...75 inches wide, 2£ per cent, below the theoretical weight; 75 inches wide up to 100 inches wide,' 5 per cent, below the theoretical weight ; when 100 inches wide and over, 1 0 per cent, above or 3 per cent, below the theoretical weight. (gr) For all plates ordered to gage...
Vista completa - Acerca de este libro

Report of Proceedings of the ... Annual Convention of the ..., Volumen 37

American Railway Master Mechanics' Association - 1901 - 622 páginas
...inches wide, when ordered to weight, shall not average more than 2^2 per cent variation above or 2}/2 per cent below the theoretical weight. When 100 inches wide and over five per cent above or five per cent below the theoretical weight. Plates under 12'/2 pounds per square...
Vista completa - Acerca de este libro

The Materials of Construction: A Treatise for Engineers on the Strength of ...

John Butler Johnson - 1898 - 886 páginas
...square foot or heavier, up to 100 inches wide, when ordered to weight, shall not average more than 2J per cent variation above or 2} per cent below the...wide and over, 5 per cent above or 5 per cent below or the theoretical weight. (f) Plates under 12 J pounds per square foot, when ordered to weight, shall...
Vista completa - Acerca de este libro

The Materials of Construction: A Treatise for Engineers on the Strength of ...

John Butler Johnson - 1898 - 906 páginas
...inches wide, when ordered to weight, shall not average more than 2£ per cent variation above or ?i per cent below the theoretical weight. When 100 inches...above or 5 per cent below the theoretical weight. (f) Plates under 12J pounds per square foot, when ordered to weight, shall not average a greater variation...
Vista completa - Acerca de este libro

The Materials of Construction: A Treatise for Engineers on the Strength of ...

John Butler Johnson - 1898 - 880 páginas
...inches wide, when ordered to weight, shall not average more than 2j per cent variation above or 24 per cent below the theoretical weight. When 100 inches...wide and over, 5 per cent above or 5 per cent below or the theoretical weight. (f) Plates under 12J pounds per square foot, when ordered to weight, shall...
Vista completa - Acerca de este libro

The Materials of Construction: A Treatise for Engineers on the Strength of ...

John Butler Johnson - 1898 - 906 páginas
...per cent below the theoretical weight ; 75 inches wide up to 100 inches wide, 5 per cent above or 3 per cent below the theoretical weight. When 100 inches wide and over, 10 per cent above or 3 per cent below the theoretical weight. ********** * (<7) For all plates ordered...
Vista completa - Acerca de este libro

Review of the American Standard Specifications, Test Pieces, and Methods of ...

Albert Ladd Colby - 1900 - 108 páginas
...to 75 inches wide, 2 1/2 per cent. above or 2 1/2 per cent, below the theoretical weight. 75 inches and over, 5 per cent. above or 5 per cent. below the theoretical weight. (j). For all plates ordered to gauge, there will be permitted an average excess of weight over that...
Vista completa - Acerca de este libro

Structural Iron and Steel: A Text-book for Architects, Engineers, Builders ...

Walter Noble Twelvetrees - 1900 - 300 páginas
...— Up to 75 inches wide, 2^ per cent. above or 2\ per cent. below the theoretical weight. 75 inches and over, 5 per cent. above or 5 per cent. below the theoretical weight. (/). For all plates ordered to gauge, there will be per mitted an average excess of weight over that...
Vista completa - Acerca de este libro

Structural Iron and Steel: A Text-book for Architects, Engineers, Builders ...

Walter Noble Twelvetrees - 1900 - 308 páginas
...Plates 12 | pounds per square foot or heavier, when ordered to weight, shall not average more than 2^ per cent. variation above or 2\ per cent. below the theoretical weight. (/;). Plates under \2\ pounds per square foot, when ordered to weight, shall not average a greater...
Vista completa - Acerca de este libro

Cambria Steel: A Handbook of Information Relating to Structural Steel ...

Cambria Steel Co - 1901 - 448 páginas
...per cent. below the theoretical weight. 75 inchet wide up to 100 inches wide, 5 per cent. above, or 3 per cent. below the theoretical weight. When 100 inches wide and over, 10 per cent. above, or 3 per cent. below the theoretical weight. c. For all plates ordered to gauge,...